50-1578TECHNICAL MANUALPELLET STOVEWINDSORSHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.PLEA
10101/2”(265 mm)81/2”(216 mm)127/8”(326 mm)83/8”(214 mm)43/8”(112 mm)EXHAUSTBase of unit to center of flue 270 mm (10 ”)Side of unit to center of f
11Figure 8: Corner Installation. 100mm(4")100mm(4")Fresh Air IntakeWall thimblemanufacturedby pellet ventmanufacturer.InstallationCORNER THR
Exhaust80mm (3") or 100mm (4")Vent PipeWall Thimble45oElbow with Screenor Termination CapHigh Temperature RTVSilicone RequiredFresh Air Inta
13InstallationVERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION (RECOMMENDED):A 45° elbow with a rodent screen may be used in place of the te
Storm CollarRoof FlashingRoof RaftersFire Stop withSupport CollarCeiling JoistVertical Vent PipeClean Out Teewith Pipe AdapterENVIRO WindsorNote:All v
15InstallationOUTSIDE VERTICAL INSTALLATIONS:To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INST
Storm CollarExisting Masonary FlueFlexible Vent Connector (usethis 1.5m (5ft) section of pipeto vent past the fireplacedamper or smoke shelf)Seal Plat
17Install blowermotor ontoexhaust blowerhousings.Completed assembly.Exhaust MotorCover PlateAccess PanelInstallationINSTALLATION WITH EXTERIOR MOUNTED
TO SUPPLY POWER TO THE EXHAUST BLOWER:Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach t
19Storm CollarRoof FlashingRoof RaftersRoof SheathingCeiling JoistVertical Vent PipeOutside VentTerminationExterior WallSheathingRain cap - ensurecap
2Table of ContentsSafety Warnings & Recommendations...3Installation...
SLIDER/DAMPER SETTING:THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE THE AIRFLOW THROUGH THE PELLET STOVE.A Qualified
21• A tall, lazy flame with dark orange tips requires more air – Open slider (pull out) slightly.• A short, brisk flame, like a blowtorch, has too m
TroubleshootingDO NOT:● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly.
23TroubleshootingüCheck vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the vacuum hose from vacuum switch. Check exh
TroubleshootingüIf the auger gear box does not turn but the motor’s armature does try to spin then the auger is jammed. – Try to break apart jam by po
25Wiring DiagramConnectThermostatHereRedRedRedRedBrownBrownBrownBrownWhiteWhiteWhiteWhiteWhiteWhiteOrangeOrangeOrangeOrangeYellowYellowGreyGreyPurpleP
Reference NumberDescriptionPart Number1 120 °F (49 °C) Ceramic Fan Temperature Sensor EC-0012 Auger Motor - 220V EF-001-220V3 High Limit Temp Sensor 2
27Reference NumberDescriptionPart NumberAuger Motor Mount 50-687Auger Plate with bushing 50-688Auger Mounting Hardware 50-68922 IEC Power Cord Inlet S
Parts List - CastReference NumberDescriptionPart Number41 Cast Ash Shelf - Painted 50-19242 Cast Front Complete (Doors & Ash Shelf) - Painted 50-2
WINDSOR - ComponentsMay 2007Parts Diagram - Components29
3Safety Warnings & Recommendations* This manual is designed for the technician in conjunction with the owner’s manual. *Please read this entire Ow
WINDSOR - Steel & CastMay 2007Parts Diagram - Steel & Cast30
31NAME OF OWNER:_________________________________________ADDRESS:_____________________________________________________________________________________
4Safety Warnings & RecommendationsCLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will vary du
5Safety Warnings & RecommendationsFRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “Air
InstallationRATING LABEL LOCATION:The rating label is located on the back of the hopper.DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:1. Check clear
7Figure 2: Windsor Dimensions. 271/8"(689mm)253/4"(653mm)257/8"(659mm)153/8"(390mm)141/4"(360mm)241/8"(614mm)Installatio
This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figure 4.Minimum Alcove width 1220mm (48 inches)Minimum Al
9hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.3. Termination must exhaust above the inlet el